MICROWAVE PHOTONIC ANGLE OF ARRIVAL MEASUREMENT MODULE BASED ON DUAL-CHANNEL TANDEM AMPLITUDE-PHASE MODULATION WITH POLARIZA-TION MULTIPLEXING AND ITS MODERNIZATION
Abstract
This article proposes a microwave photonic module for measuring the angle of arrival (AOA) of echo signals in telecommunications and communication systems integrated with sensor and radar systems. This module enables convenient and accurate acquisition of information by comparing the phase of the beat envelopes of signals from two channels separated by polarization and converting their difference into power. The module utilizes two parallel tandem amplitude-phase modulators (TAPMs), implemented using series-connected Mach-Zehnder amplitude and phase modulators, to obtain dual-frequency signals with a suppressed carrier and a difference frequency equal to the microwave frequency of reflection signals (active mode) or information sources (passive mode) from adjacent elements of a linear antenna array. The first part of the article presents a comparative analysis of existing microwave photonic methods and tools for measuring AOA, and describes the operating principle of the proposed module, evaluating its advantages and disadvantages. The target characteristics to be achieved include measuring the amplitude gain in the range from 0 to π/2 with an error of less than ±1.7 mrad under ideal computational and laboratory conditions using classical phase-to-power conversion techniques. The application of a new technique of phase conversion based on a constant phase switching of the reference and measurement signals allowed us to propose the use of a neural network for measuring the amplitude gain. The results of applying the neural network allowed us to reduce the error in measuring the phase of the reflected signal to ±1.25 mrad over virtually the entire measurement range. The second part of the article discusses the modernization of the module with the transition to the implementation of a TAFM based on a single amplitude modulator in each channel. The obtained characteristics are not significantly worse than those presented in the first part, with an extended range of unambiguous АОА determination from -π/2 to π/2 with an error of less than ±3.5 mrad under ideal computational and laboratory conditions, which allows us to speak about the effectiveness of simplifying and reducing the cost of the system as a whole.

This work is licensed under a Creative Commons Attribution 4.0 International License.